SC-AHLT low Ade mostly powder
SC-AHLT low Ade mostly powder kdorfman Tue, 02/04/2020 - 13:26High concentration agar is difficult to work with.
- Tends to boil over, so needs a lot of water in the autoclave pan
- Hard to get into solution - frequently needs re-autoclaving
- So viscous that bubbles don't rise to the surface
So
- mix the ingredients that can't be autoclaved in as little water as possible
- Only use high concentration stock solutions for micro-ingredients
Per Liter:
dry ingredient | g |
---|---|
SC-AHLT | 1.64 |
YNB | 1.7 |
Ammonium sulfate | 5 |
glucose | 20 |
stock solutions | mL |
---|---|
10X Adenine hemi sulfate | 2.5 |
50X Tryptophan | 20 |
100X Histidine HCl | 10 |
plus water to 150 mL
filter sterilize
Autoclave
- 20 g agar
- 850 mL water
Mix and pour
Mark with one green and one blue line.